    • ApplicationsHVAC-system pumping and control; general purpose pumping; industrial/process pumping and control (water or glycol based)
    • DescriptionPipe-mounted 2-pump unit with integrated intelligent controls for space-saving installation, superior energy performance, and parallel-pumping or full redundancy operation. Saves up to 75% in energy over comparable traditional constant speed or variable frequency operated pump installations. Remote services through internet to enhance reliability and sustain optimal performance over life of pumps.
    • Materials
      • Ductile iron e-coated casing
      • Stainless steel impeller
      • Sintered silicon carbide mechanical seal
    • ConfigurationOn-board Intelligent Variable Speed controls with Sensorless control. Split-coupling design and outside balanced or inside single spring mechanical seal. Controls enclosure UL type 12 or UL type 4X for outdoor applications. 1-10hp range standard with DEPM motors that reduce losses by more than 20% over NEMA Premium efficiency.  Network capable for remote performance management services.
    • Performance rangeUp to 900 USgpm (56 L/s) in parallel flow and 160 ft (48 m) head (composite curves available)
    • Temperature300˚F (150˚C)
    • Power Range0.33 hp to 10 hp (0.25 kW to 7.5 kW)
    • Size1″ to 3″ (25 mm to 80 mm)
    • ApplicationsFire-protection of buildings and other built infrastructure
    • DescriptionThe Armstrong Vertical In-line (VIL) FirePak line features the full range of VIL fire pumps with electric motor and controller. All mounted, piped, and wired on a base at the factory. The complete package is designed to fit through a standard door.
    • MaterialsMetal base, piping, pump, and control panel; switchgear; electric motor
    • ConfigurationOptions available include jockey pump and jockey pump controller. 50 Hz and 60 Hz designs. UL, ULC, and/or FM certification
    • Performance range50 – 1500 USgpm
    • ApplicationsFire-protection of buildings and other built infrastructure
    • DescriptionThe Horizontal Split-Case (HSC) FirePak offering features the full range of Armstrong HSC fire pumps, electric or diesel-driven, and controller. All mounted, piped, and wired on a base at the factory.
    • MaterialsMetal base, piping, pump, and control panel; switchgear; electric motor/ diesel engine
    • ConfigurationOptional features include jockey pump, jockey pump controller city by-pass loop, flow meter loop, main relief valve plus waste cone, and diesel fuel tank. 50 Hz and 60 Hz electric versions
    • Performance range500 – 3000 USgpm
    • ApplicationsPre-fabricated HVAC systems for a variety of applications including chiller plants, boiler plants, pumping stations, energy transfer stations, substations, cooling tower applications, fire pump systems, and water-based process applications.
    • DescriptionArmstrong pre-fabricated HVAC Systems include a combination of: structural, process equipment, controls, electrical gear, and even environmental enclosures that are designed and fabricated to customer specifications.  In addition, the program offers a full range of catalogued pre-engineered designs selectable from our on-line software – which includes 2D and 3D CAD files for immediate drag-and-drop into mechanical room designs.

      Engineered to order (custom) HVAC Systems such as Fluid Management Systems, Heat Transfer Packages, and Packaged Plant Rooms can be ordered by contacting your local representative.

    • Performance rangeSystem capabilities address process requirements up to header sizes of 36” (900 mm), and multiple fluid streams with parallel or serial configurations
    • TemperatureSystems can be designed for indoor or outdoor applications in environments ranging from -40oF (-40oC) up to +120oF (52oC)
    • Power RangeUnlimited
    • SizeUnlimited
    • ApplicationsFire-protection of buildings and other built infrastructure
    • ConfigurationAvailable as single electric, single diesel, one electric plus one diesel, two electric, or two diesel configurations. Optional features include tamper switches, test header lines, city by-pass and flow meter loops with all required piping and valves.
    • BenefitsArmstrong enclosed fire pump packages combine a fire pump system, piping, electrical and exhaust components, and a weather-proof enclosure. Pump packages are designed, built and tested in a controlled ISO 14000 certified factory environment and shipped to site ready for installation
    • ApplicationsPre-fabricated HVAC systems for a variety of applications including chiller plants, boiler plants, pumping stations, energy transfer stations, substations, cooling tower applications, fire pump systems, and water-based process applications.
    • DescriptionArmstrong pre-fabricated HVAC Systems include a combination of: structural, process equipment, controls, electrical gear, and even environmental enclosures that are designed and fabricated to customer specifications.  In addition, the program offers a full range of catalogued pre-engineered designs selectable from our on-line software – which includes 2D and 3D CAD files for immediate drag-and-drop into mechanical room designs.

      Engineered to order (custom) HVAC Systems such as Fluid Management Systems, Heat Transfer Packages, and Packaged Plant Rooms can be ordered by contacting your local representative.

    • Performance rangeSystem capabilities address process requirements up to header sizes of 36” (900 mm), and multiple fluid streams with parallel or serial configurations
    • TemperatureSystems can be designed for indoor or outdoor applications in environments ranging from -40oF (-40oC) up to +120oF (52oC)
    • Power RangeUnlimited
    • SizeUnlimited
    • ApplicationsHeating and cooling, plumbing and waste water, especially in tight spaces in mechanical rooms where parallel pumping is needed with or without optional standby pump
    • DescriptionThe Armstrong 8200 ARMPak pumping packages are specifically designed to meet the requirements of chilled water and heating water systems in commercial buildings. They are available in duplex and triplex configurations, with fixed or variable speed control. Suitable for space constrained installation, parallel pumping and optional stand-by pump
    • Configuration4280V or 4200V pumps, Flo-Trex valves, optional IPS controls and variable frequency drive(s) with bypasses, NEMA 1 control panel (including gauges and interconnecting piping), headers, valves, and fittings
    • Size3”, 4” and 6” header sizes
    • ApplicationsEnergy optimization of HVAC chilled-water plants with partial or all variable speed equipment and an existing building automation system (BAS) or central plant controller.
    • DescriptionThe Armstrong OPTI-VISOR interfaces seamlessly with any existing building automation to maximize overall plant efficiency – without replacing or reconfiguring existing componentry. The OPTI-VISOR harmonizes the interplay of existing componentry through leading-edge control algorithms for maximum plant performance.
    • ConfigurationIntegrates with all brands of chillers, pumps, and building automation systems
    • Performance rangeNo limitations in plant size and cooling capacity
    • Power RangeNo limitations in plant size and cooling capacity