All Posts

Shopview:
List
Reset Filters

Showing 41–48 of 140 results, including child brands

    • ApplicationsFire-protection of buildings and other built infrastructure
    • ConfigurationAvailable as single electric, single diesel, one electric plus one diesel, two electric, or two diesel configurations. Optional features include tamper switches, test header lines, city by-pass and flow meter loops with all required piping and valves.
    • BenefitsArmstrong enclosed fire pump packages combine a fire pump system, piping, electrical and exhaust components, and a weather-proof enclosure. Pump packages are designed, built and tested in a controlled ISO 14000 certified factory environment and shipped to site ready for installation
    • ApplicationsPre-fabricated HVAC systems for a variety of applications including chiller plants, boiler plants, pumping stations, energy transfer stations, substations, cooling tower applications, fire pump systems, and water-based process applications.
    • DescriptionArmstrong pre-fabricated HVAC Systems include a combination of: structural, process equipment, controls, electrical gear, and even environmental enclosures that are designed and fabricated to customer specifications.  In addition, the program offers a full range of catalogued pre-engineered designs selectable from our on-line software – which includes 2D and 3D CAD files for immediate drag-and-drop into mechanical room designs.

      Engineered to order (custom) HVAC Systems such as Fluid Management Systems, Heat Transfer Packages, and Packaged Plant Rooms can be ordered by contacting your local representative.

    • Performance rangeSystem capabilities address process requirements up to header sizes of 36” (900 mm), and multiple fluid streams with parallel or serial configurations
    • TemperatureSystems can be designed for indoor or outdoor applications in environments ranging from -40oF (-40oC) up to +120oF (52oC)
    • Power RangeUnlimited
    • SizeUnlimited
    • ApplicationsHeating and cooling, plumbing and waste water, especially in tight spaces in mechanical rooms where parallel pumping is needed with or without optional standby pump
    • DescriptionThe Armstrong 8200 ARMPak pumping packages are specifically designed to meet the requirements of chilled water and heating water systems in commercial buildings. They are available in duplex and triplex configurations, with fixed or variable speed control. Suitable for space constrained installation, parallel pumping and optional stand-by pump
    • Configuration4280V or 4200V pumps, Flo-Trex valves, optional IPS controls and variable frequency drive(s) with bypasses, NEMA 1 control panel (including gauges and interconnecting piping), headers, valves, and fittings
    • Size3”, 4” and 6” header sizes
    • ApplicationsEnergy optimization of HVAC chilled-water plants with partial or all variable speed equipment and an existing building automation system (BAS) or central plant controller.
    • DescriptionThe Armstrong OPTI-VISOR interfaces seamlessly with any existing building automation to maximize overall plant efficiency – without replacing or reconfiguring existing componentry. The OPTI-VISOR harmonizes the interplay of existing componentry through leading-edge control algorithms for maximum plant performance.
    • ConfigurationIntegrates with all brands of chillers, pumps, and building automation systems
    • Performance rangeNo limitations in plant size and cooling capacity
    • Power RangeNo limitations in plant size and cooling capacity
    • ApplicationsCommercial or industrial closed-loop systems, including HVAC chilled-water systems, boiler systems, cooling tower systems, or process water loops.
    • DescriptionThe Armstrong Intelligent Fluid Management System (iFMS) integrates superior pump- and control technology into a single pumping solution yielding both compact and carefree installation as well as superior energy performance. iFMS is ideally suited for partial or all variable speed chilled-water plant applications (variable primary flow, variable secondary flow, variable condenser water flow). In combination with Parallel Sensorless control iFMS saves 30% or more in energy over any other parallel pumping configuration available today.
    • ConfigurationUp to 4 pumps in one unit. Catalogue-based pre-engineered solutions or designed to customer specification. Integrated control system (IPS 4000, IPC 11550) or connecting to chiller plant/BMS control. Optional single point power panel
    • ApplicationsAir-cooled or water-cooled chilled water system automation for data centers
    • DescriptionThe Armstrong Design Envelope EVERCOOL system is an integrated automation and optimization solution for data center chiller plants. Designed to meet the Uptime Institute requirements for all Tiers of data centers, this mission critical platform has also been standardized for speed to market and quick deployment.
    • ConfigurationIntegrates with all brands of chillers, pumps, and automation systems. Installs directly with chiller plant equipment. If preferred, the EVERCOOL connects with any data center information management (DCIM) system or central building automation system (BAS).
    • Performance rangeStandardized solution controls up to six chillers, six cooling towers, six chilled water pumps, six condenser water pumps (when applicable) and redundant sensors and valves.
      Project-specific requirements may include free-cooling, water-side economizer, chilled water storage tanks, etc.
      No limitations in plant size and cooling capacity.
    • ApplicationsHVAC-system pumping and control, general purpose pumping (water or glycol based)
    • DescriptionA retrofit of an existing constant speed Armstrong Vertical In-line to a Armstrong Design Envelope Vertical In-line pump utilizing the existing casing and replacing all other components.

      Pipe-mounted with integrated intelligent controls for continued space savings and superior energy performance.  Saves up to 70% in energy compared to traditional constant speed pump installations.

    • Materials
      • Cast-iron or ductile iron casing
      • Bronze impeller
      • Sintered silicon carbide mechanical seal
    • ConfigurationOn-board intelligent variable speed controls with Sensorless control.  Split coupling and outside balanced or inside single spring mechanical seal.  Controls enclosure UL type 12 or UL type 4X for outdoor applications.
    • Performance range25- 25,000 US gpm (1.5 to 1500 L/S) flow, 10 – 300 ft (3 to 90m) head  (composite curves available)
    • TemperatureUp to 300oF (150oC)
    • Power Range1 hp to 1250 hp (0.75 kW to 900 kW)
    • Size1.5” to 15” (40 mm to 400 mm)
    • ApplicationsHVAC-system pumping and control; general purpose pumping; industrial/ process pumping and control (water or glycol based)
    • DescriptionBase mounted end-suction horizontal pumping unit with integrated intelligent controls for easier installation and superior energy performance. Saves up to 75% in energy over comparable traditional constant speed or variable frequency operated pump installations. Units up to 10hp (7.5kW) include integral vibration isolators.
    • Materials
      • Cast-iron or ductile iron casing / ductile iron e-coated casing on units 1-10hp
      • Bronze or stainless steel impeller on units 1-10hp
      • Sintered silicon carbide mechanical seal
    • ConfigurationOn-board Intelligent Variable Speed controls with Sensorless control. Controls enclosure UL Type 12 (IP55) indoor applications. 1-10hp (0.75-7.5 kW) range standard with Design Envelope permanent magnet (DEPM) motors that reduce losses by more than 20% over NEMA Premium efficiency. Network capable for remote performance management services.
    • Performance range25 to 1000 USgpm (1.5 to 63 L/s) flow; 10 to 160 ft (3 to 48 m) head (composite curves available)
    • Temperature250oF (121oC)
    • Power Range1 hp to 10 hp (0.75 kW to 7.5 kW)
    • Size1.25″ to 6″ discharge (32 mm to 150 mm)